COORDINATE SYSTEM X, Y, Z rectangular Cartesian
 
UNITS Gauss, Tesla (switchable)
 
FIELD CANCELLING
  1.  SC20-AC Sensor(s)
    Components cancelled X, Y, Z field components
    Dynamic range (X & Y) 80 mG (8 µT) pk-pk
    Dynamic range (Z) 60 mG (6 µT) pk-pk
    Field reduction ratio 50 X (typical) at 50/60Hz
    Bandwidth 0.5Hz - 5000Hz
    Detector noise limit 2 µG (0.2 nT) pk-pk
 
  2.  SC20-Wideband DC sensor(s)
    Components cancelled X, Y, Z field components
    Ambient DC field ± 2 G (± 200 µT) max
    Dynamic range (X & Y) ± 40 mG (± 4 µT) incremental
    Dynamic range (Z) ± 30 mG (± 3 µT) incremental
    Field reduction ratio 50 X (typical) at 50/60Hz (incremental)
  200 X (typical) at DC (incremental)
    Bandwidth DC - 2500 Hz
    Noise and Drift DC drift/24 hours    < 100 µG (10 nT) after 2 hour warm-up
  DC noise (0.0001- 0.01 Hz)    30 µG (3 nT) pk-pk (typical)
  Spot noise (at 50 Hz)    1 µG/√Hz (0.1 nT/√Hz)
 
FIELD MEASUREMENT
  Types 1. Real time field
  2. AC - true RMS amplitude
  3. Incremental DC (with DC sensor)
  Display
    RMS & DC 3.5 digit LED panel meters
    Sensor dynamic range > 20 mG pk-pk
    Note: RMS & DC measurement ranges are limited by sensor pk-pk range
    Meter range (reading) 0-19.99 mG (1.999 µT) RMS
  ± 19.99 mG (1.999 µT) DC
  Accuracy
    Note: sensors are calibrated with 50 Hz, 10mG RMS square wave field.
    RMS ± 1.0 % of reading ± 20 µG (2 nT)
    Incremental DC ± 5.0 % of reading
  Real time field monitor
    Signals X, Y, Z, real time field
    Scaling 1.0 V/mG
    Range >± 10 Volts
    Source resistance 10 kOhms
    Connectors 3 X BNC
    Bandwidth 5 Hz - 20 kHz (AC sensor )
  DC - 5 kHz (DC sensor)
  Trip range adjustment
    AC-RMS 0 - 2.0 mG (200 nT)
    DC 0 - 5.0 mG (500 nT)
 
POWER 120/240 V 50/60 Hz, 100 VA