| System |
| |
Carrying Case Size |
58 x 36 x 19 cm (23 x 14 x 7.5 in) approx. |
| |
Weight |
11 kg (24 lb) approx. including typical laptop PC. |
| |
|
|
| Laptop Personal Computer |
| |
Processor |
2.53GHz Dual Core Pentium min (or equivalent) |
| |
Memory |
2GB rec. |
| |
Free Hard Disc |
120GB typ. |
| |
Optical Drive |
CD/DVD reader (DVD+R compatible) |
| |
Operating System |
Windows XP/Vista/7 |
| |
| Core System: SC11/SI/USB (Sensor Interface) |
| |
Inputs |
|
| |
|
MAG1, MAG2 |
3-axis magnetic field sensor (2 x SC20 sensor) |
| |
|
VIB1, VIB2, VIB3 |
3-axis vibration (3 x Wilcoxon 731A) |
| |
|
MIC |
Precision microphone (Brüel & Kjær, 4190/2669L) |
| |
|
AUX |
BNC voltage input, DC coupled, ±10 V range, 100 kΩ input impedance |
| |
Anti-aliasing filters |
20 kHz |
| |
Power |
100 - 240 V AC, 50 - 60 Hz, 0.25A max |
| |
| 3-axis Magnetic Field Sensor: SC20/DCMR |
| |
Co-ordinate System |
X, Y, Z rectangular Cartesian |
| |
Bandwidth |
DC - 10 kHz |
| |
Ambient Field Range |
±2 G (±200 µT) |
| |
Dynamic Range |
±20 mG (2 µT) |
| |
Noise Limit |
DC: 5 µG (0.5 nT) Pk-Pk typ. (0.0001 - 0.01 Hz) |
| |
|
AC: 0.1 µG/√Hz (10 pT/√Hz) RMS typ. at 50 Hz |
| |
Accuracy |
±1 % (after >2hour warm up). (±5 % cold) |
| |
| 3-axis Magnetic Field Sensor: SC20/AC |
| |
Co-ordinate System |
X, Y, Z rectangular Cartesian |
| |
Bandwidth |
5 Hz - 20 kHz |
| |
Dynamic Range |
40 mG (4 µT) Pk-Pk |
| |
Noise Limit |
1 µG (100 pT) RMS over 25Hz-20kHz band |
| |
Accuracy |
±1 % |
| |
| 3-axis Magnetic Field Sensor: SC20Fast/AC |
| |
Co-ordinate System |
X, Y, Z rectangular Cartesian |
| |
Bandwidth |
25 Hz - 20 kHz |
| |
Dynamic Range |
40 mG (4 µT) Pk-Pk |
| |
Noise Limit |
1 µG (100 pT) RMS over 25Hz-20kHz band |
| |
Accuracy |
±1 % |
| |
| Vibration Sensor: Wilcoxon 731A Accelerometer |
| |
Type |
Wilcoxon Research, model 731A |
| |
Bandwidth |
0.1 - 500 Hz |
| |
Dynamic Range |
2 m/s2 (0.2g'sα) Pk-Pk (in this system) |
| |
Noise Limit |
7 µm/s2 RMS max. |
| |
|
0.35 µm/s RMS at 1Hz, 0.11 µm/s RMS at 5Hz |
| |
|
0.07 µm RMS at 1Hz, 0.0035 µm RMS at 5Hz |
| |
Accuracy |
±5 % (with gain calibration file) |
| |
| Acoustic Sensor: B&K 4190/2669L Precision Microphone |
| |
Type |
Brüel & Kjær, Condenser microphone 4190, Pre-amplifier 2669L |
| |
Bandwidth |
1.5 Hz - 20 kHz |
| |
Dynamic Range |
110 dB (in this system) |
| |
Noise Limit |
20 dB (in this system) |
| |
Accuracy |
±1 dB 3 Hz - 20 kHz |
| |
| Programs (General) |
| |
Channel modes |
4 channel & 8 channel |
| |
Channels |
4 channel mode X, Y, Z, A
8 channel mode X1, Y1, Z1, A1, X2, Y2, Z2, A2 |
| |
Clipping |
Audio/visual indication |
| |
Pause control |
Freeze/resume instrument operation |
| |
Calibration panel |
Set channel mode, Add/select sensors, set ranges, calibrate offsets, microphone self check, add/edit user defined units, set export file options. |
| |
Setup file |
Open/save instrument controls |
| |
Export |
Export results for SCplot or spreadsheet |
| |
Print window |
Print current screen display |
| |
Help |
Context help on controls, online help file |
| |
| Oscilloscope |
| |
Amplitude Units |
| |
|
Magnetic Field |
mG, nT, µT, mA/m, A/m |
| |
|
Vibration |
µg'sα, mg'sα, µm/s2, mm/s2 |
| |
|
Acoustic |
mPa, Pa |
| |
|
Voltage |
mV, V, user defined units |
| |
|
Resultant |XYZ| |
Magnetic Field, Vibration, Voltage units |
| |
Time ranges (ms) |
0.5, 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000, 2000 |
| |
Bandwidth (Hz) |
20,000 for time ranges 0.5, 1, 2, 5
At least 100,000/(time range) for other time ranges |
| |
Digital Meter |
RMS, Peak to Peak (all channels) |
| |
Trigger |
Auto/Manual level, +/- edge, source, one-shot |
| |
Capture indicator |
Indicates progress of data acquisition |
| |
| Spectrum Analyser |
| |
Displays |
Waveform (autoscaling), Spectrum |
| |
Select |
Highlight and attach cursor to selected signal |
| |
Amplitude units |
|
| |
|
Magnetic field |
mG, nT, µT, mA/m, A/m |
| |
|
Vibration |
µg'sα, mg'sα, µm/s2, mm/s2, µm/s, mm/s, nm, µm |
| |
|
Acoustic |
mPa, Pa, dB, dBa, dBC |
| |
|
Voltage |
mV, V, user defined units |
| |
|
Resultant |XYZ| |
Magnetic Field, Vibration, Voltage units |
| |
Amplitude ranges |
1, 2, 5, 10, 20, 50, 100, 200, 500, log full scale |
| |
Frequency ranges |
20, 25, 30, 40, 50, 60, 80, 100, 120, 160, 200, 250, 300, 400, 500,
600, 800, 1000, 1200, 1600, 2000, 2500, 3000, 4000, 5000, 6000,
8000, 10000, 12000, 16000β, 20000, Hz full scale |
| |
Number of points |
200, 250γ, 400, 500γ, 800, 1000γ, 1600, 2000γ, 3200β, 4000β |
| |
Accuracy |
Frequency: ±0.01% ±0.02 div |
| |
Waveform windows |
None, Hanning, Flat top |
| |
Waveform windows |
None, Hanning, Flat top |
| |
Spectrum modes |
RMS, 0-Pk, Pk-Pk, PSD, Third Octave (RMS, 0-Pk, Pk-Pk) |
| |
Combine spectra |
Average/Peak, Max no. spectra |
| |
Cursor modes |
Total RMS between 2 tracking cursors, 10 harmonic cursors |
| |
Capture indicator |
Indicates progress of data acquisition |
| |
Specification files |
Create, edit, add & remove. Compare with measurements. |
| |
Data logging |
Start: Now, At time, Triggered by flat level, Triggered by spec |
| |
|
Stop: Period, File size, Disk space |
| |
|
Min. time step: 1 minute |
| |
| Chart Recorder |
| |
Position |
Set or zero vertical positions |
| |
Amplitude units |
|
| |
|
Magnetic field |
mG, nT, µT, mA/m, A/m |
| |
|
Vibration |
µg'sα, mg'sα, µm/s2, mm/s2, µm/s, mm/s, nm, µm |
| |
|
Acoustic |
mPa, Pa, dB, dBA, dBC |
| |
|
Voltage |
mV, V, user defined units |
| |
|
Resultant |XYZ| |
Magnetic Field, Vibration, Voltage units |
| |
Page length |
5, 10, 25, 50, 100, 250, 500 s |
| |
Chart length |
20 Pages |
| |
Max Bandwidth |
(Bandwidth may be reduced by bandwidth controls) |
| |
|
Magnetic field |
DC - 2.5δ kHz for Sensor SC20/DCMR
5 Hz - 2.5δ kHz for Sensor SC20/AC
25 Hz - 2.5δ kHz for Sensor SC20Fast/AC |
| |
|
Vibration |
0.1 Hz - 500 Hz |
| |
|
Acoustic (Precision Microphone) |
1.5 Hz - 2.5δ kHz |
| |
|
Voltage |
DC - 2.5δ kHz |
| |
Bandwidth controls |
XYZ/A upper/lower for all modes except narrow band |
| |
Narrow band filter |
Centre frequency, f0 range: 1 Hz - 1250 Hz
Accuracy: ±1% within pass band (f0 ± 3%)
Attenuation: 60 dB min. in stop band (f0 ± 20%) |
| |
Chart modes |
Waveform, RMS, Peak to Peak, Narrow band RMS, Narrow band Pk-Pk. |
| |
Markers |
Time, text string |
| |
Clear |
Clear chart data |
| |
Buffer indicator |
Indicates state of data acquisition buffer |
| |
Update modes |
Page, scroll |
| |
Chart palette |
Pan, zoom, format, reset and clear chart |
| |
Data logging |
Start: Now, At time, Triggered
Stop: Period, File size, Disk space
Log rate limit, time step: ≥ (page length)/500 |
| |
| α g’s are units of the acceleration due to gravity |
| β 4 Channel mode only |
| γ Not available on 20000 Hz range in 8 channel mode |
| δ 1.25 kHz in 8 channel mode |
|