SC11 Analysis System
Magnetic Field, Vibration and Acoustics - In-depth analysis from the compact, all-in-one easy to use system

Comparison of SC11 Basic system and SC11 Sensor Interface


The following table indicates the main differences between the SC11 Basic System and the SC11 Sensor Interface. This will enable you to choose the system most suitable to your requirements.

Magnetic Field Sensors
  SC11 AC Sensor SC20 DC Sensor MEDA µMAG
Used with SC11 Basic System only SC11 Sensor Interface only SC11 Basic System or SC11 Sensor Interface
Low cut off freq. 1 Hz (min 0.01 Hz*) DC DC
High cut off freq. 5 kHz 5 kHz 100 Hz
Axes 3 3 1
Dynamic range 80 mG Pk-Pk 40 mG Pk-Pk 4000 mG Pk-Pk
Zero offset range N/A ±2000 mG ±750 mG
Offset method Settles in 1s (max 100s*) Resets in 12s Zero adjust knob
Power From computer Universal AC PP3/9V adapter
* In Chart Recorder
 
Vibration Sensor
  SC11 Basic System SC11 Sensor Interface
Sensor type Wilcoxon 731A accelerometer Wilcoxon 731A accelerometer
Number supported 1 Up to 3
 
 
Acoustic Sensor
  Radio Shack 33-2050 or 33-4050 Sound Level Meter Brüel & Kjær 4190/2669L Precision Microphone
Used with SC11 Basic System or SC11 Sensor Interface SC11 Sensor Interface only
Dynamic range (in SC11 systems) 50 dB to 126 dB 20dB to 103dB
Bandwidth (in SC11 systems) 32 Hz - 2 kHz 1.5 Hz - 2 kHz